Nurses Call Monitoring System

Nurse Call Monitoring System- Digital Series D-20/ D-30

 

BPS offers Digital Call indicator and Monitoring Systems for Hospitals and Nursing Homes.
The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience.
These are installed in many leading hospitals for years and are working with full satisfaction of each hospital. Very simple to install and maintain.

 

System Over View:
Each bed is provided with call station board consisting of Bed push confirmation light and re-set push. The patient can make call form the push switch. On receipt of call at the Digital Display Board, Confirmation Light on the Call Station will be on. This ensures that there is no problem in wiring. The call received at Display Board can only be re-set by the attending nurse from the re-set push provided at the bed side of patient (Call Station Board). On attending the call, the confirmation light and the bed number at the monitor will be switched off.
If any call remains pending over a set period the particular number will be hi-lighted by flushing the digit & buzzer installed at the floor in-charge/matron will be activated.This will help in avoiding any negligence in services.

 

The system will comprise of
a) Call Station Board,                         Nurse
b) Door Indicator,
c) Digital Display board,
d) Data Logger Card
e) UPS system

 

Call Station Board
is consisting of Bed push confirmation light and re-set push. It is designed for standard modular box.

 

Door Indicator:
is consisting of cluster of LEDs mounted in specially designed cabinet. It has Tangle/ Round Red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the Nurses moving by to attend immediately even before going to the Nurses Station.

 

Digital Display board:
The Digital display board is call monitor console which is installed at the Nurse center. All Call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one Nurse Station. It has soft buzzer which alerts the attendment on receipt of any new calls.

 

Call Station Board
is consisting of Bed push confirmation
light and re-set push. It is designed
for standard modular box.

Data Logger Card:
This is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thus
generated helps the Hospital Management in taking appropriate decisions. The card is supported with specially developed softwar which is installed in the computer.

 

UPS system.
The system has its own specially designed UPS. It is consisting of a SMF type 12 v 7 ah battery,automatic battery charger and allied accessories.

 

Unique advantages are:

 

Low voltage operation:
The incoming mains is converted to 12 V.D.C. in the Power Supply section and  patient is not put to danger even due to accidental snatching of wires.

 

Digital Display of Bed Nos:
with 2-3 digit Bright LED displays,bed number can be easily noticed from a distance.

 

Non Attendance timer:
Each call received activates a built in timer and after a specified time, it activates a Buzzer.

 

Battery backup:
To facilitate making call even during power cut, the system is provided with a battery backup.

 

Re-set at patients bed:
To re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance.

 

Cost effective solution:
This system is very cost effective for installation and maintenance

 

Computer Connectivity :
with add-on Card, the system can record each event and helps management in taking appropriate and logical decision.

 

Ordering information BPS D20 / D30 Digital Nurses Call Monitoring System.

 

       Item                         Description    Model No.    Quatity     requried
Callstation Board With 3 ” x 3″ MS Box, Acralic cover,
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
BNCM-PB1 each bed = 1 set
With 3 ” x 3″ MS Box, Modular cover,
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
BNCM-PB2 (PB1 or PB2)
   DoorIndicator with 8 Nos Red LEDs, Red Acrylic cover
suitable for connecting up to 8 beds
in one room
BNCM-DU-1     Optionalforeachroom
with 3 colour LEDs, Flash/ study / Off
functions, Acknowledge Push, Acralic
cover suitable for connecting up to 4
beds in one room
BNCM-DU-2
 Digital Display  Board   with  2digit display with one No 2 Digit display card, Acralic cover,in MS box of 275 x 125 x 50 mm BNCM-D2CA up to 6 beds
with two No. 2 Digit display card, Acralic cover,in MS box of 275 x 225 x 50 mm BNCM-D2CB up to 12 beds
with three No.2 Digit display card, Acralic cover,in MS box of 300 x 325 x 50 mm BNCM-D2CC up to 18 beds
with four No. 2 Digit display card, Acralic cover,in MS box of 300 x 460 x 50 mm BNCM-D2CD up to 24 beds
with five No.2 Digit display card, Acralic cover,in MS box of 350 x 550 x 50 mm BNCM-D2CE up to 30 beds
with six No.2 Digit display card, Acralic cover,in MS box of 350 x 6000 x 50 mm BNCM-D2CF up to 36 beds
  Digital  Display  Board    with   3digit  display with oneNo. 3 Digit display card, Acralic cover,in MS box of 300 x 125 x 50 mm BNCM-D3CA up to 5 beds
with two No.3 Digit display card, Acralic cover,in MS box of 300 x 225 x 50 mm BNCM-D3CB up to10 beds
with three No.3 Digit display card, Acralic cover,in MS box of 300 x 350 x 50 mm BNCM-D3CC up to 15 beds
with four No.3 Digit display card, Acralic cover,in MS box of 300 x 450 x 50 mm BNCM-D3CD up to 20 beds
with fiveNo.3 Digit display card, Acralic cover,in MS box of 300 x 550 x 50 mm BNCM-D3CE up to 25 beds
with six No. 3 Digit display card, Acralic cover,in MS box of 600 x 475 x 50 mm BNCM-D3CF up to 30 beds
       Data Logger  card Computer interferance card with softwar fitted in enclosure BNCM-DLC -1 up to 36 beds
.UPS sytem Power supply with Automatic Battery charger, SMF 12 V. 7 AH battery BNCMUPS1 up to 36 beds=1 set
  Wires from
bed to
call
station
       2 pair telephone wire as per distance from beds
to call station

 

Nurse Call Monitoring System Series 10

Series I-10 Nurse Call Monitor System is cost effective solution for Hospitals and Nursing Homes with limited budget.
The system is tried tested and is working for over 20 years in many hospitals.

Features:Nurse Call LED

• Low Voltage Operation
• Digital Display of Bed Nos
• Re-set at Patients Bed
• Non Attendance Timer
• Battery Backup
• Low Maintenance Cost
• Computer Connectivity
• Compact and Flexible

System Over View:

Each bed will have call station board consisting of Bed push confirmation light and re-set push. The patient can make call form the push switch. On receipt of call at the Display Board, Confirmation Light on the Call Station will be on.This ensures that there is no problem in wiring.
The call received at Display Board can only be re-set by the attending nurse from the re-set push provided at the bed side of patient (Call Station Board). On attending the call,the confirmation light and the bed number at the monitor will be switched off. If any call remains pending over a set period the particular number will be hi-lighted by change in color of light & buzzer installed at the floor in-charge/ matron will be activated. This will help in avoiding any negligence in services.

The system is consisting of following
a) Call Station Board
b) Indicator Board
c) Door Indicator
d) UPS system

Call Station Board:
is consisting of Bed push confirmation light and re-set push. It is designed forstandard modular box.
Door Indicator:
is consisting of cluster of LEDs mounted in specially designed cabinet.It has Tangle/ Round Red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the Nurses moving by to attend immediately even before going to the Nurses Station.
Call Indicator Board:
The call indicator board is to be installed at the Nurse center.Call received from any bed will be displayed by the respective indicator with Green Led against bed number marked.
UPS:
It consists of a SMF type 12 v, automatic 7 ah battery charger and allied accessories.

Ordering information BPS I-10 Nurses Call Monitoring System

Item Description Model No. Quantity Required
   Call station  Board With 3 ” x 3″ MS Box, Acralic cover, BNCM-PB1    each bed=1 set(PB1 orPB2)
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
With 3 ” x 3″ MS Box, Modular cover, BNCM-PB2
confirmation Light, Re-set push &
Bed Push with 2 meter flexible wire
   DoorIndicator with 8 Nos Red Leds, Red Acralic cover BNCM-DU-1     Optionalforeachroom
suitable for connecting up to 8 beds
in one room
with 3 colour LEDs, Flash/ study / Off BNCM-DU-2
functions, Acknowledge Push, Acralic
cover suitable for connecting up to 4
beds in one room
    CallindicationBoard with one Indicator card, Acralic cover, BNCM-I-10CA Up to 10 beds
Number marking fitted in MS box
of 200 mm x 75 mm
with two Indicator card, Acralic cover, BNCM-I-10CB Up to 20 beds
Number marking fitted in MS box
of 200 mm x 150 mm
with three Indicator card, Acralic cover, BNCM-I-10CC Up to 30 beds
Number marking fitted in MS box
of 200 mm x 225 mm
with three Indicator card, Acralic cover, BNCM-I-10CD Up to 40 beds
Number marking fitted in MS box
of 200 mm x 300 mm
UPS sytem Power supply with Automatic Battery BNCMUPS1 Up to 40 beds=1set
charger, SMF 12 V. 7 AH battery
Wires from     bed to call station 2 pair telephone wire as per distance fr

 

Micro- Controller based Nurse Call Monitoring System Series 640

 SYSTEM HIGHLIGHTS

Each call from each bed must be attended-
attended  within the time limit.
If not?
How to monitor  and fix-up responsibility.

To ensure the practice is followed, the system must be reliable and must have built in mechanism to point out delay in action.

Nurses Call Monitoring System series 640 informs the nursing staff the sequence of call  received thus minimizing any over due call. The call register maintains sequence in which call from different bed are received.

The first call pending is displayed with Big 2” 7 segment display. 4 other calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending.

If any call is pending beyond set time, the number starts blinking. it also activates a buzzer to draw attention of the nursing staff. If call remains pending even beyond 2nd limit, rate of blinking is intensified to bring notice of problem.

Nurse_call_monitoring_system_640_image

• Micro-controller based system

• Serial display of calls received
-1st call displayed with 2″ Height LED
display, Next 4 calls in sequence on side
column, Further pending  calls- on
Scrolling 3 Digit 7 segment displays.

• Soft tone buzzer
- alerts receipt of new call

• Elegant look

• Compact and flexible
- Table- wall mountable.

• Built in Non Attendance Timer
- Pending calls flash
- Long pending calls flash at higher rates

• Modular Bed Side console
- Easy installation in std. Modular cabinet

• Status Indicators and buttons
- Ready, Call & Wait LED indication
on board, with Call & Reset switch

• Elegant patient remote  

• Low Voltage Operation

- The system works on 12 V. D.C hence
patient is not put to danger even due to
accidental snatching of wires.

• Reset at patient bed
- re-set button installed near the patient.

• Compact and flexible
- The system requires very low space and
is flexible to accommodates up to 64 beds.

 

Next Generation System from
Industry Leader

Leaders in Nurses Call Monitoring System in India “BPS” team is presenting the latest technical innovation in the line.
The system is designed   by our in house team to suit Indian conditions.

SYSTEM OVER VIEW

Series 640 consists of mainly the following sub-systems:

a)    Call station Board
b)     Patient Remote hand set
c)    Door indicator
d)    Toilet Pull Cord
e)    Master Controller Hub
f)    Nurses Monitor Console

Call Station BoardNurse Call Monitoring System 1

Each bed is provided with call station board. This is housed in standard console. It has push switches to call and re-set the call.

LED indications for Ready(Green), Call(Red), and Wait(Yellow) are provided. Ready LED indicates that the system is ok and call can be made. If there is any problem with wiring, it will not glow. This is built in system to give instant check of any system or wiring fault.

LED marked Call lights up when the call is made. Once the call is made and it is registered with the controller hub, LED marked Wait glows indicating call has reached Nurse station.Nurse Call Monitoring System 2

Patient Remote hand set
From call station, remote Patient Hand Set is  provided so that the patient can make call form his bed.
Remote hand set  has push to make call. LED indication for Ready, Call and Wait are provided.

 

Door indicator
Door indicator is installed out  side the room to indicate call pending in the room. This facilitates nursing staff to attend on way to Nurse Station. One Door indicator can announce pending call for
Door_Indicator_Imageup to 8 beds   in the same room. Door indicators are available with many features like color LEDs, hold switch etc.
Toilet Pull Cord:
Toilet Pull Cord with Indicator & Rope. Standard length of rope is 1.5m. This pull cord is installed in side the toilet. Patient can use the pull cord in toilet.

 

Master Controller Hub:
Controller Hub is central unit installed near Nurse  Monitor Console. It is consisting of one
Micro-processor central Controller card, one connector card for up to 16 beds SMPS.
Wires from all beds are terminated on connector PCB. It receives information fromN
each bed and signals the Console to display the information.
Nurses Monitor Console
The call monitor console will be installed at the Nurse center. Call received from any bed will be displayed by the respective bed number by 3 digit 7 segment LED display. It can be mounted on wall or table stand. The first call pending is displayed with Big 2” 7 segment display. Other 4 calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down.
Any call attended is automatically erased and display is replaced with the next call pending.

 

Connections:
Two  pair telephone cable will be required to connect each bed  to display board. Telephone type socket  is punched to wires from each bed. Mains supply of 230 V AC is required at Controller Hub.

Low voltage operation:
The incoming mains is converted to 12 V. D.C. in the Power Supply section and patient is not put to danger even due to accidental snatching of wires.

Re-set at patients bed:
To re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance.

Compact and flexible:
The system requires very low space and is flexible to add on as the number of beds increases. Marking on he indication board can be custom designed for easy location and is editable.

OUR EXPERTISE
Nurses call monitoring Systems and Queue Management Systems by team “BPS” is installed in all the leading hospitals in Eastern India.
With over 15 years of feed back from actual working condition in hospitals, continuous improvement in design, innovation of technology we are presenting Series 640-The most advanced Nurses Call monitoring System.
The system is designed with utmost reliability, dependability, safety, and flexibility in mind.

 

                                                                                   ORDERING INFORMATION
           Item                                                     Description       Model No. Quantity reburied
 Call station Board with Membrane push switches for call and Re-set buttons
& LEDs for Ready, Call and Wait, Connector for console connection
and connector for Patient remote hand set
BNCM-PB640A each bed = 1 set
        Patient
Remote Handset
with flexible wire of 2 meters, Telephone type Jack connector,
switch for call and indication for Ready, Call & Wait
  BNCM-PB640R each bed = 1 set
  Door Indicator with 8 nos Red LEDs, Red Acrylic cover for connecting up to 8 beds
in one room
     BNCM-DU-1      Optional
with 3 colour LEDs, Flash/ study / Off functions,  Acknowledge Push,
Acrylic cover suitable for connecting up to 4 beds in one room
     BNCM-DU-2   for each Room
     Toilet Pull
Cord
Toilet Pull Cord with Indicator
Rope length standard 1.5 m
    BNCM-TPC1   for each Toilet
  Master Controller
Hub Type-1
With one Micro-processor central Controller card, One connector card
for up to 16 beds, power supplies (SMPS) housed in hinged cabinet
 BNCM-MCH640A   up to 16 beds
Master Controller
Hub Type-2
With one Micro-processor central Controller card, two connector card
for up to 32 beds power supplies (SMPS) housed in hinged cabinet
 BNCM-MCH640B   up to 32 beds
Master Controller
Hub Type-3
With one Micro-processor central Controller card, three connector card
for up to 48 beds power supplies (SMPS) housed in hinged cabinet
 BNCM-MCH640C   up to 48 beds
Master Controller
Hub Type-4
With one Micro-processor central Controller card, four connector card
for up to 64 beds power supplies (SMPS) housed in hinged cabinet
 BNCM-MCH640D   up to 64 beds
  Nurse Monitor
Console
with one 2″ height & 4 Nos 3/4″ height LED display
suitable for wall mounting and with table stand
 BNCM-NCH640A   up to 64 beds
Data Logger Card Computer interference card with software
fitted in enclosure
   BNCM-DLC-2      Optional
up to 64 beds
   Wires from bed
to call station
2 pair telephone wire        as per distance from beds to
call station

 

Download Catalogue

Comments are closed